ModularControllerResetProcedure
1),Removethe(5)screwfromthe
faceplate,RedArrows
2),UseEXTREMECAUTION:if
powerisappliedtounit,Pull
controllerouttorevealthe
connector,
RedArrow.
Pressthesmalltabincenterof
connectortoreleasethe
connectorfromthecircuitboard.
RedArrow
ProductionControllerresetsteps:ThisstepwillNOTaffectthestateoftheoutlets.
1. Use a paper clip or similar object, Press and hold a micro-switch in the hole next to the (SEL) button
under the LCD screen or between 2
nd
& 3
rd
LED (BLUE Arrow) disconnect the cable to the module for
5 seconds, (RED Arrow)
2. Continue to press micro-switch, connect cable to module, wait 10 seconds and release switch.
3. Serial in to the module. If it appears the controller did not reset, still contains old data, perform reset
again but increase the disconnect time to 10 seconds and wait time to 15 seconds.